Gas work on this side of the corridor starts with the fuel supply, because a building that has been empty for months has a supply system that has also been idle.
Propane and the tank
A propane tank that ran low over winter can carry moisture and oil through the line. The symptoms look like a failing appliance: a weak flame, a pilot that lights and dies, a burner that rumbles.
The regulator and the tank's own state are checked before the heater is condemned.
Pilots and the closed season
A standing pilot goes out when the air in a line reaches it. Relighting once, per the label on the unit, is reasonable. A pilot that will not hold after two attempts points to a thermocouple, a gas valve or a venting problem, and only the first of those is a small job.
Venting and combustion air
A sealed cabin gives a burner less air than an open house. Signs that it is not venting properly: condensation on the inside of windows near the unit, a smell of exhaust, soot at the draft hood, or a CO alarm.
Any of those means the unit is shut off until the flue and the air supply are corrected. Carbon monoxide is the one failure in this trade that kills people in their sleep.
Pressure
Gas pressure is measured at the appliance, not estimated from how the flame looks. A manifold pressure that is low explains a burner that will not carry the load; one that is high explains sooting and overheating.
What is not advised
Opening a gas valve to smell for a leak, taping a thermocouple, or running a unit with the flue disconnected to "see if it works". Gas repairs are for someone with the instruments and the licence to do them.
When the fix is a replacement
A gas valve on an old unit, a rusted flue collar, or a tank that has already been repaired once often costs more to keep than to replace — and on a seasonal building, the maths favours doing it before the season, not during it.