Gas water heaters in Bumblebee are usually propane, and the appliance's health depends on three things outside itself: the air it can draw, the flue above it, and the supply behind it.
The pilot's evidence
A pilot that will not hold points at the thermocouple or thermopile, the orifice, or the gas supply. An electronic ignition unit that locks out has failed to prove flame, which can be the igniter, the sensor, the valve — or the vent.
One relight attempt, per the label, is sensible at the start of a season. A second attempt without knowing why the first failed is not.
Air in a sealed cabin
A tightly built cabin with a solid closet door and no air opening starves a burner. The signs are a yellow flame, soot at the draft hood, spillage when the unit starts, and a pilot that keeps going out.
Combustion air is an inspection item for the county, and it is the item most often missing in older installations.
The flue under snow
A vent termination that sits close to the roof surface gets buried in a snowy winter. From inside, that looks like a heater fault — spillage, odour, soot, a pilot that will not stay lit — and the risk it creates is carbon monoxide.
If a CO alarm sounds, everyone leaves and the gas utility and 911 are called. The flue is corrected before the unit runs again.
Propane under load
A tank that is nearly empty, a regulator that frosts, or a line sized for a smaller appliance produce the same symptom: it runs, then it quits. Testing pressure at the appliance separates a supply problem from a control problem.
Order of work