Gas at group scale is a supply question before it is an appliance question. A propane tank feeding several buildings, a long run to the last unit, a regulator that has been there since the buildings were wired for light — those shape what the burner does.
Supply and pressure
Pressure is measured at the appliance inlet and at the manifold. A reading that falls below spec when two units fire together points to the supply: an undersized line, a tired regulator, or a tank that is low on a cold morning.
Low tank pressure in winter is a propane fact of life here, and it looks exactly like a failing gas valve.
Pilots after the closed season
Air in a line is the ordinary reason a standing pilot will not light in the spring. After one relight attempt per the label, the next checks are the thermocouple, the gas valve, and the draft.
A pilot that lights and then dies when the burner comes on is a venting or air-supply symptom, and it is worth taking seriously in a building where people sleep.
Carbon monoxide in shared buildings
Bunkhouses and bathhouses hold people close to the equipment. A CO alarm is an evacuation, not a diagnostic. The causes are familiar: a blocked or disconnected flue, reversed draft, a burner with the wrong orifice for the fuel, or a room with no combustion air.
Every one of those is corrected before the unit runs again.
Orifices and fuel
A unit set up for natural gas will not run correctly on propane, and the reverse. Where a property has changed fuel or replaced a tank, the appliance orifices and the regulator spring are matched to what is actually being delivered.
What the repair is not
Taping a thermocouple, drilling a vent, or running a unit with the flue off to see whether it lights. Those are the shortcuts that put carbon monoxide into a room full of people.
Replacement signals
A rusted flue collar, a cracked heat exchanger, a gas valve on an obsolete unit. On a seasonal property those are worth resolving in the shoulder months, while the buildings are empty.