Tankless units are usually chosen for space and efficiency, and in Cow Creek they bring one local complication to the front: the condensate has to go somewhere sensible in a building that already has water problems.
Condensate, routed properly
A condensing unit produces acidic water whenever it fires. The line must fall continuously to a drain or to outside air, must not run uphill, and must not end where it will freeze or be buried in snow.
Discharging into a crawlspace that is already damp is the wrong answer — it adds moisture and acid to the exact place the building struggles with.
Scale and the well
The exchanger plates with hardness, and the symptom is a slow loss of temperature rather than a fault code. Descaling with a pump restores it; leaving it long enough ends in an overheated exchanger.
The interval follows the water, and a well supply here is not gentle.
Freeze protection and power
The freeze cycle needs power. A cabin closed with the breaker off in December has no protection, and a cracked exchanger is a spring discovery.
Flow thresholds
Below the unit's minimum activation flow the burner stops. Low-flow fixtures and partly closed valves can sit under it, which reads as an intermittent fault until someone measures the flow.
Venting
The termination has to clear the season's snow. A blocked flue produces codes, sooting and spilled combustion products, and it is corrected before the unit is used again.
Order
Condensate, water quality, gas pressure, flow, flue. Most tankless calls here are decided in the first two.