A water heater that has sat in an unheated building for eight months is not in the state it was left in. Commissioning it — a short list, done before the building fills up — is the difference between a quiet season and a cold one.
Before the water goes on
Look at the floor under the unit and the inside of the pan. Damp there is the first thing to explain, and it is much cheaper to explain it while the building is empty and the supply is still off.
Then the flue: a cap or a screen that has come loose, a bird's nest, snow packed against the termination. A blocked flue is a combustion problem, not a cosmetic one.
Pressure and temperature relief
The relief valve should be exercised — lifted and allowed to reseat — so it does not seize shut over the closed season. The discharge pipe should run to a safe place, and if that pipe is full of ice, that gets cleared before anything fires.
Water on, slowly
Refill before restoring power or lighting, then open a hot tap to let air out of the tank. An element energised in a dry tank burns out in seconds, which is the most common self-inflicted failure in a seasonal building.
Sediment, from a well
Private supply deposits mineral material at the bottom of a tank and on the elements or the burner. Flushing through the drain valve until the water runs clear is the routine, and on this water the interval follows what comes out, not a printed schedule.
A tankless exchanger that has plated up responds to a descale with a pump kit; it does not respond to a flush.
Gas and the pilot
A standing pilot that will not hold after a winter is usually air in the line or a thermocouple, and occasionally a venting fault. Light it once following the label. If it goes out again, that is a call rather than a repetition.
The season's record
Note what the drain looked like, whether the anode was pulled, and any water in the pan. Next spring, that note is what tells you whether the tank is ageing normally or getting ahead of you.