How often a tankless water heater needs flushing
The interval follows your water, not a printed schedule. What hardness does to a heat exchanger, how to tell it needs descaling, and how the job is done.
Tankless units are sold on the promise of endless hot water and no tank to rust. What the marketing tends to skip is that the exchanger is a set of narrow passages with hot water on one side and flame on the other, and minerals collect in it.
What scale does
Hard water leaves calcium and magnesium behind as it heats. In a tank that material settles to the bottom; in a tankless exchanger it coats the inside of the passages.
Coated, the metal transfers heat less efficiently. The unit responds by firing harder and running longer, and the water at the tap gets cooler at the same setting. Left long enough, a passage narrows enough to restrict flow, and then the unit short-circuits on its own safety limits.
So how often?
The honest answer is that the interval is set by the water, not by the calendar. A widely used starting point is annual descaling, which suits moderately hard supply and a household that uses the unit daily.
Two things move it sooner: harder water, and heavier use. A property on a private well, with several bathrooms and a seasonal peak, is the case where a year is generous.
Two things move it later: soft water and light use. A cabin that runs the unit a few weeks a year does not accumulate scale at the same rate as a family home — but it does sit with water in the exchanger, which brings the freeze question instead.
Reading your own unit
The practical method is to watch the temperature. Note the setting that gives comfortable hot water when the unit is clean, then check it again in six months. A setting that has crept up is scale.
Some units display inlet and outlet temperatures and a flow rate; a widening gap between what the unit is asked for and what it delivers is the same signal, in numbers.
The descale, in order
Isolate the unit with its service valves, connect a pump kit to the flush ports, circulate the manufacturer's descaling solution through the exchanger for the specified time, then rinse with clean water before returning the unit to service.
Two details decide whether it works: the solution is the manufacturer's, not a substitute, and the rinse is thorough. Descaling solution left in the exchanger is a call the following week.
Units without service valves need them fitted before the first flush, which is a job in itself and worth doing at installation rather than later.
When descaling is not the answer
If the exchanger has cracked — usually from freezing, not from scale — no amount of flushing helps. A building that freezes needs the unit drained for the closed season, following the maker's procedure including the inlet filter and any drain plugs.
Flow problems have a different cause again: a loaded inlet filter, a weak pump, or a fixture below the unit's activation rate. Those are diagnosed in tankless water heater repair, and they look like scale until someone measures the flow.
The short version
Start with annual descaling, then let your own temperature readings set the interval. On hard well water, expect to shorten it. If you cannot remember the last time it was done, that is the answer.